| Motor type |
GYS500DC2
-T2
|
GYS101DC2
-T2
|
GYS201DC2
-T2
|
GYS401DC2
-T2
|
GYS751DC2
-T2
|
| Rated output [kW] |
0.05 |
0.1 |
0.2 |
0.4 |
0.75 |
| Rated torque [N·m] |
0.159 |
0.318 |
0.637 |
1.27 |
2.39 |
| Max. torque [N·m] |
0.478 |
0.955 |
1.91 |
3.82 |
7.17 |
| Rated speed [r/min] |
3000 |
| Max. speed [r/min] |
5000 |
| Moment of inertia [kg·m2] |
0.0192×10-4 |
0.0371×10-4 |
0.135×10-4 |
0.246×10-4 |
0.853×10-4 |
| Rated current [A] |
0.85 |
0.85 |
1.5 |
2.7 |
4.8 |
| Max. current [A] |
2.55 |
2.55 |
4.5 |
8.1 |
14.4 |
| Winding insulation class |
Class B |
| Operation duty type |
Continuous |
| Degree of enclosure protection |
Totally enclosed, self-cooled
(IP67, excluding the shaft sealing and connectors) |
| Terminals (motor) |
With 0.3 m flexible leads and
connectors |
| Terminals (encoder) |
With 0.3 m flexible leads and
connectors |
| Overheat protection |
Not provided (The servo
amplifier detects temperature.) |
| Mounting method |
By securing motor flange IMB5
(L51), IMV1 (L52), IMV3 (L53) |
| Shaft extension |
Straight shaft with a key |
| Paint color |
N1.5 |
| Encoder |
17-bit encoder |
| Vibration level |
V5 or below |
| Installation place, altitude |
For indoor use, 1000 m or below |
| Ambient temperature, humidity |
-10 to +40 °C, 90 % RH or
below (without condensation) |
| Vibration resistance [m/s2] |
49 |
| Mass [kg] |
0.45 |
0.55 |
1.2 |
1.8 |
3.4 |