Always Changes For The Better! 

Fuji Factory Automation Products: Fuji PLC, Fuji LVS, Fuji PLC, Fuji Inverter, Fuji Servo, Fuji HMI, Fuji POD Fuji Inverter, PLC, Servo, HMI, LVS, Come From:JonWeb Technology
  中文访问 HOME CONTACT Selling  Price Fuji Inverter Fuji PLC Fuji HMI Fuji Power Distribution Fuji Servo User Manual
 
Jonweb FA:
Siemens: PLC / HMI / Inverter
Allen Bradley PLC
Mitsubishi PLC / VFD / AC Servo...
Semiconductor: IGBT / Diode...
Yaskawa Inverters
Fuji AC Servo System
Cisco Router & Switche
 
On Requested:
Schneider PLC
Mean Well
APC UPS Power Supply
Proface HMI
LG PLC / Inverter
VIPA PLC / HMI
Sanyo Denki
BTB Inverter
Fluke Meters
Tektronix Oscilloscopes
Agilent
Hioki Tester
Panasonic
Omron
Toshiba
Hitachi
Idec
Sanken
Koyo
Meiden
Nikki Denso
Keyence
Oriental
 
Also Supply:
 -> Latex Pillows & Mattress
 -> Fuel Additive - STR2020
Contact Method
China/Beijing
    TeL:+86-10-86360099
            +86-10-62988280
    Fax:+86-10-62985883
MSN:
  cn5130@hotmail.com 
Email :
  ZhengJon@yahoo.com 
Any Call:
  +86-13001958500
Skype ID:  japanfa.com

More Detail...

 
GuestBook
  Send messages to us online.
Send messages to us online.
 
PLC Unlock, PLC Keyword Cracker, PLC Password Cracker, PLC Cracker, Crack file.
Sell your FA to China?
 
> Fuji Products Center   >  Fuji Inverters > FRENIC-ECO  > Common specifications
Common specifications

Item
Explanation
Remarks
Related function code
Output frequency Setting range Maximum frequency 25 to 120Hz   F03
Base frequency 25 to 120Hz   F04
Starting frequency 0.1 to 60.0Hz   F23
Carrier frequency • 0.75 to 15kHz (200V/400V:0.75 to 22kW)
• 0.75 to 10kHz (200V/400V:30 to 75kW)
• 0.75 to 6kHz (200V/400V:90 to 500kW)
The carrier frequency may drop automatically according to the ambient temperature or output current to protect the inverter. This protective operation can be canceled by function code H98. F26
F27
H98
Accuracy (Stability) • Analog setting: ±0.2% of maximum frequency (at 25±10°C)
• Keypad setting: ±0.01% of maximum frequency (at -10 to +50°C)
   
Setting resolution • Analog setting: 1/1000 of maximum frequency (ex. 0.06Hz at 60Hz, 0.12Hz at 120Hz)
• Keypad setting: 0.01Hz (99.99Hz or less), 0.1Hz (100.0Hz or more)
• Link setting: Selectable from 2 types
  •1/20000 of maximum frequency (ex. 0.003Hz at 60Hz, 0.006Hz at 120Hz)
   •0.01Hz (fixed)
 Setting withUP,Downkeys.  
Control Control method V/f control    

Voltage/freq. characteristic

Possible to set output voltage at base frequency and at maximum output frequency
(common spec.). AVR control can be turned ON or OFF.
Three-phase 200V: 80 to 240V
Three-phase 400V: 160 to 500V
F03toF05
(Non-linear V/f setting)
1 point (Arbitrary voltage and frequency can be set.) Three-phase 200V: 0 to 240V/0 to 120Hz
Three-phase 400V: 0 to 500V/0 to 120Hz
H50,H51

Torque boost

Torque boost can be set with the function code F09. Set when 0, 1, 3, or 4 is selected at F37. F09, F37
(Load selection)
Select application load type with the function code F37.
0: Variable torque load 1: Variable torque load (for high starting torque) 2: Auto-torque boost
3: Auto-energy-saving operation (variable torque load in acceleration/deceleration)
4: Auto-energy-saving operation (variable torque load (for high starting torque) for acceleration/deceleration)
5: Auto-energy-saving operation (auto-torque boost in acceleration/deceleration)
  F09, F37
Starting torque 50% or over    
Start/stop Keypad
operation
Start (FWD/REV) and stop withRUNSTOPkeys Keypad (standard) F02
Start and stop withFWD/REVSTOPkeys Multi-function keypad (optional) F02
External signals (7 digital inputs): Forward (reverse) rotation, stop command (capable of 3-wire
operation), second operation command, coast-to-stop command, external alarm, alarm reset, etc.
  E01toE05
E98,E99
Link operation: Operation through RS485 communication and Field Bus communication (option)   H30, y98
Operation command switch: Remote/local switch, link switch, second operation command switch    
Frequency setting Keypad operation: Can be set with
 UP,Downkeys
  F01, C30
External potentiometer: Can be set with the external resistor (1 to 5k?, 1/2W) Connected to analog input terminals 13, 12,
11. A separate variable resistor is necessary.
 
Analog input Can be set with external voltage/current input.
0 to +10V DC (0 to +5V DC)/0 to 100% (terminal 12, V2)
4 to 20mA DC/0 to 100% (terminal C1)
0 to +5V DC:change (200%) in analog
input gain setting. +1 to +5V DC:adjustable
with bias/analog input gain
F18, C50, C32toC34, C37toC39, C42toC44
Multistep frequency: Selectable from 8 steps (step 0 to 7)   C05toC11
UP/DOWN operation: The frequency rises or lowers while the digital input signal is turned on.   F01,
C30
Link operation: Can be set with RS485 communications and field bus communications (option).   H30,
y98
Frequency setting change: Two types of frequency settings can be switched with an external signal (digital input).
Changeover between remote and local (keypad operation) or frequency setup through communication is also possible.
  F01,
C30
Auxiliary frequency setting: Inputs at terminal 12, C1 or V2 can be added to the main setting
as auxiliary frequency settings.
  E61toE63
Reverse action: The digital input signal and function code setting sets or switches between
the forward and reverse actions.
• +10 to 0V DC/0 to 100%(Terminal 12, V2) • 20 to 4mA DC/0 to 100%(Terminal C1)
  C53
Acceleration / deceleration
time
0 to 3600s
• Acceleration and deceleration pattern can be selected from 4 types: Linear,
S-curve (weak), S-curve (strong), Curve (constant output max. capacity).
• Shutoff of the operation command coasts the motor to decelerate and stop.
  F07, F08
H07
H11
Frequency limiter High and low limiters can be set (setting range: 0 to 120Hz) Selection can be made between continuation of operation and
stopping at frequencies equal to or smaller than the lower limit.
F15, F16
H63
Bias frequency Bias of set frequency and PID command can be set in the range between 0 and ±100%.   F18,
C50toC52
Gain for frequency setting The analog input gain can be set in the range from 0 to 200%. Voltage signals (terminal 12, V2) and current
signal (terminal C1) can be set independently.
C32,C34,
C37
C39,C42,
C44
Jump frequency setting 3 operation points and their common jump hysteresis width (0 to 30Hz) can be set.   C01toC04
Restart after momentary
power failure
•The inverter restarts upon recovery from power failure without stopping the motor.
• In the "operation continuation mode," recovery of the power supply is waited for while the output frequency slightly drops.
• Selection can be made among starting at 0Hz, starting at the frequency immediately before the momentary power failure,
and starting at a set frequency for the starting method after power recovery.
  F14



H13toH16,
H92,H93
Current limit Keeps the current under the preset value during operation.   F43,F44
Line/inverter switching •Line/inverter switching (starting at line frequency) can be made with a digital input signal (SW50, SW60).
• A built-in line/inverter switching sequence performs sequence control with a digital input signal (ISW50, ISW60) to
output a signal (SW88, SW52-1, SW52-2) for controlling an external magnetic contactor (MC). As a built-in
sequence, two types can be selected, including the one switching automatically to the line upon an inverter alarm.
  J22
PID control Capable of PID regulator control for process   E61toE63
J01toJ06
J10toJ19
Process commands
• Key operation (UP and DOWN keys):0 to 100%
• Analog input (terminal 12, V2):0 to +10V DC/0 to 100%
• Analog input (terminal C1):4 to 20mA DC/0 to 100%
• UP/DOWN (digital input):0 to 100%
• Communication (RS485, bus option):0 to 20,000/0 to 100
 

Supplier:   JonWeb Technology Trade CO.,LTD 
Room 902, Shangdi Garden 23, Shangdi East Road, Haidian District, Beijing, China (Zip: 100085)
Easy Call: +86-13001958500 (24hours Hotline) ,    Tel: +86-10-62988280 / 86360099,      Fax: +86-10-62985883
MSN:    cn5130@hotmail.com   /   Email: ZhengJon@Yahoo.com    /  Skype Chat  ID:  
japanfa.com


Stronger on: Siemens PLC / Siemens Inverter / Siemens HMI , Mitsubishi PLC / Mitsubishi Inverter / Mitsubishi AC Servo , Fuji AC ServoSemiconductor / IGBT / Diode , Allen Bradley / Allen Bradley PLC,   VIPA PLC / VIPA HMI Yaskawa Inverter , PLC Cables Cisco / Cisco Router / Cisco SwitchUPS / APC UPS , Latex Pillows / Latex Mattress  , STR2020  Etec.